UPS On-Line 10 000VA PF1 Office LCD 8X IEC C13, 2X IEC C19, metal case DUST-FREE

Guarantee: 24 mth
Description: UPS On-Line 10 000VA PF1 Office LCD 8X IEC C13, 2X IEC C19, metal case DUST-FREE The Armac Tower Office On-Line PF1 Dust-Free series has been designed for businesses, server rooms, design studios, and workstations equipped with devices requiring stable power. The free-standing Tower enclosure allows the UPS to be placed close to the protected equipment without the need to install it in a telecommunications rack.On-line Topology and 0 ms Transfer TimeThe UPS uses VFI on-line topology with double energy conversion. The power drawn from the mains is first converted into direct current and then converted back into stable alternating current. As a result, connected devices are not powered directly from an unstable electrical grid.When the input voltage fails, the UPS immediately draws energy from the batteries without any interruption in the power supply. The transfer time is 0 ms, allowing a server, workstation, or network system to continue operating without restarting or losing unsaved data.The pure sine wave output allows the UPS to safely power devices equipped with active PFC circuits, advanced switching power supplies, and electronic equipment requiring a stable voltage waveform.Highest Power Factor - Power Factor 1.0A power factor (PF) of 1.0 ensures highly efficient use of the UPS's available power. Depending on the selected model, the user gets either 6000 W or 10,000 W of active power, making it easier to select a UPS for extensive IT infrastructure.The high efficiency of the device - reaching 95% in Line mode, 94.5% in Battery mode, and 98% in ECO mode - helps effectively reduce energy losses and the amount of heat generated during operation. This is particularly important in server rooms and technical facilities, where the UPS often operates continuously around the clock.Wide Input Voltage RangeWith on-line technology, the power supplied from the mains is first converted into direct current and then back into stable alternating current. This prevents disturbances present at the input from being directly transferred to connected devices.In the event of a power failure, the UPS continues to supply power from the batteries without any transfer time. Protected servers, storage arrays, and network devices can therefore continue operating without restarting, data loss, or interruption of ongoing processes.The wide input voltage range of 110 to 300 VAC allows the UPS to maintain stable operation even in installations exposed to frequent voltage drops and surges.Full device power is available with an input voltage ranging from 176 to 276 VAC. In the 110 to 176 VAC range, the available power is gradually reduced, while at an input voltage of 276 to 300 VAC, the maximum load is 50%.The output voltage can be set within the range of 208 to 240 VAC.Dust ProtectionThe Dust-Free design limits the ingress of dust and fine particles into the device. This is particularly important in offices, manufacturing plants, warehouses, and other environments where the air may contain dust, toner, or paper particles.The dust filter can be removed and cleaned. Keeping the filter in good condition supports proper airflow, helps reduce the accumulation of contaminants on electronic components, and lowers the risk of reduced cooling performance.Extended Battery SystemTower models are equipped with 20 VRLA AGM lead-acid batteries, each rated at 12 V with a capacity of 9 Ah. The sealed battery design reduces maintenance requirements and enables safe operation in professional environments.A connector for an additional battery module allows the system to be expanded with external battery packs. This makes it possible to adapt the backup runtime to the requirements of a specific installation, such as a server room, monitoring system, network infrastructure, or equipment responsible for maintaining business continuity.Ten Output SocketsTower models are equipped with a total of 8 IEC C13 and 2 IEC C19 output sockets. The large number of outputs allows several devices to be protected simultaneously without the need for an extensive set of additional power strips.The UPS can power, among other things, servers, disk arrays, computers, monitors, network switches, and other components of a workstation or technical infrastructure.Easy Operation MonitoringThe USB Type-B and RS-232 ports enable communication between the UPS and a computer or management system.The PowerManager II software allows users to monitor the device's operating parameters, check the status of the power supply and batteries, and respond to events related to mains power failures. This allows administrators to monitor the system without having direct physical access to the UPS.Remote UPS management over a LAN network is enabled by a dedicated SNMP network card module.

Manufacturer's index: T/10000I/PF1/DF
EAN: 5901969429978
Manufacturer: Armac

Guarantee: 24 mth
Description: UPS On-Line 10 000VA PF1 Office LCD 8X IEC C13, 2X IEC C19, metal case DUST-FREE The Armac Tower Office On-Line PF1 Dust-Free series has been designed for businesses, server rooms, design studios, and workstations equipped with devices requiring stable power. The free-standing Tower enclosure allows the UPS to be placed close to the protected equipment without the need to install it in a telecommunications rack.On-line Topology and 0 ms Transfer TimeThe UPS uses VFI on-line topology with double energy conversion. The power drawn from the mains is first converted into direct current and then converted back into stable alternating current. As a result, connected devices are not powered directly from an unstable electrical grid.When the input voltage fails, the UPS immediately draws energy from the batteries without any interruption in the power supply. The transfer time is 0 ms, allowing a server, workstation, or network system to continue operating without restarting or losing unsaved data.The pure sine wave output allows the UPS to safely power devices equipped with active PFC circuits, advanced switching power supplies, and electronic equipment requiring a stable voltage waveform.Highest Power Factor - Power Factor 1.0A power factor (PF) of 1.0 ensures highly efficient use of the UPS's available power. Depending on the selected model, the user gets either 6000 W or 10,000 W of active power, making it easier to select a UPS for extensive IT infrastructure.The high efficiency of the device - reaching 95% in Line mode, 94.5% in Battery mode, and 98% in ECO mode - helps effectively reduce energy losses and the amount of heat generated during operation. This is particularly important in server rooms and technical facilities, where the UPS often operates continuously around the clock.Wide Input Voltage RangeWith on-line technology, the power supplied from the mains is first converted into direct current and then back into stable alternating current. This prevents disturbances present at the input from being directly transferred to connected devices.In the event of a power failure, the UPS continues to supply power from the batteries without any transfer time. Protected servers, storage arrays, and network devices can therefore continue operating without restarting, data loss, or interruption of ongoing processes.The wide input voltage range of 110 to 300 VAC allows the UPS to maintain stable operation even in installations exposed to frequent voltage drops and surges.Full device power is available with an input voltage ranging from 176 to 276 VAC. In the 110 to 176 VAC range, the available power is gradually reduced, while at an input voltage of 276 to 300 VAC, the maximum load is 50%.The output voltage can be set within the range of 208 to 240 VAC.Dust ProtectionThe Dust-Free design limits the ingress of dust and fine particles into the device. This is particularly important in offices, manufacturing plants, warehouses, and other environments where the air may contain dust, toner, or paper particles.The dust filter can be removed and cleaned. Keeping the filter in good condition supports proper airflow, helps reduce the accumulation of contaminants on electronic components, and lowers the risk of reduced cooling performance.Extended Battery SystemTower models are equipped with 20 VRLA AGM lead-acid batteries, each rated at 12 V with a capacity of 9 Ah. The sealed battery design reduces maintenance requirements and enables safe operation in professional environments.A connector for an additional battery module allows the system to be expanded with external battery packs. This makes it possible to adapt the backup runtime to the requirements of a specific installation, such as a server room, monitoring system, network infrastructure, or equipment responsible for maintaining business continuity.Ten Output SocketsTower models are equipped with a total of 8 IEC C13 and 2 IEC C19 output sockets. The large number of outputs allows several devices to be protected simultaneously without the need for an extensive set of additional power strips.The UPS can power, among other things, servers, disk arrays, computers, monitors, network switches, and other components of a workstation or technical infrastructure.Easy Operation MonitoringThe USB Type-B and RS-232 ports enable communication between the UPS and a computer or management system.The PowerManager II software allows users to monitor the device's operating parameters, check the status of the power supply and batteries, and respond to events related to mains power failures. This allows administrators to monitor the system without having direct physical access to the UPS.Remote UPS management over a LAN network is enabled by a dedicated SNMP network card module.
Basic
Special functions: Awaryjne wyłączenie (EPO) Alarmy dźwiękowe Zimny start Automatic Voltage Regulation (AVR)
Environment requirements: Recommended ambient temperature: 0 to 40°C Recommended ambient humidity: 0 to 95%
I/O connectors:1 x EPO1 x RS-232 (COM)1 x USB (Type B)
Apparent power:10 kVA
Active power:10000
Voltage:12
Output power ports:2 x IEC-C198 x IEC-C13
No. of batteries:20
Weight:72
Color:Black
Filters / protection:CircuitOverloadSuppressionSurge
The shape of the output voltage:Full sine wave
Input power ports:Input terminal
UPS Architecture:on-line
Software:PowerManager II
Chassis type:Tower
Number of phases input:1 (230V)
Dimensions:524 x 251 x 604 mm
Battery capacity:9